Elevator Control Boards: Why They Fail & What Repair Involves

When an elevator starts acting up, shutting down without warning, flashing random error codes, or stopping a few inches above or below the floor, the problem often traces back to a single part: the control board. It is one of the most important components in your elevator, and one of the least understood by the people who own and manage the building.

This article covers what a control board is, why these boards fail, what a repair actually involves, and how to decide between repairing, replacing, and modernizing.

What Is an Elevator Control Board?

Your elevator’s control board is essentially its brain; it is the circuit board that manages nearly everything the elevator does: moving the car between floors, processing call buttons, timing the doors, and overseeing the safety circuits that keep everyone inside protected.

Newer elevators run on boards built around microprocessors, while older systems may still rely on relay-based logic. Either way, the control board works constantly behind the scenes. When it is healthy, you never think about it. When it starts to fail, almost anything the elevator does can be affected, which is why it helps to understand how these boards work and what keeps them running.

3 Common Reasons Why Elevator Control Boards Fail

Control boards are built to last, but they live in a demanding environment and don’t last forever. Most failures come down to three things:

1. Heat, Dust, & Humidity

Heat is the most common culprit. Machine rooms get warm, and the warmer a board runs, the faster its components wear out. The small parts that store and regulate power, called capacitors, are especially sensitive and give out sooner in hot conditions.

Dust and humidity make it worse. When dust settles on a board and mixes with moisture in the air, it creates a thin film that electricity can travel across where it shouldn’t, which leads to shorts and strange, hard-to-trace faults.

2. Power Surges & Voltage Swings

The electronics on a control board are sensitive to the quality of the power feeding them. A surge from a nearby lightning strike, a spike on the building’s electrical supply, or an unstable power grid can damage the board’s chips, burn out components, or knock out its internal power supply instantly.

3. Age & Wear

Even in good conditions, a control board ages. Capacitors dry out, relay contacts wear down, and years of heating up and cooling off can crack the tiny soldered connections that hold the board together. Constant vibration adds to it over time. This is the slow kind of failure, and it is one reason elevators in older buildings tend to cause more trouble than newer ones.

What Elevator Control Board Repair & Troubleshooting Involve: 5 Key Steps

Repairing an elevator control board involves more than identifying and swapping out a damaged part. Technicians must follow electrical safety procedures, inspect the board, diagnose the fault, determine the right fix, and confirm the elevator operates safely afterward. Here are the five key steps the repair process usually involves:

1. Electrical Isolation & Safety Precautions

Before inspecting or working on a control board, technicians follow the appropriate safety procedures. That includes isolating the electrical supply, applying lockout/tagout procedures, and verifying the equipment is safe to work on. These precautions help prevent electrical shock and unintended elevator movement during the work.

2. Visual Inspection & Diagnostic Checks

Technicians inspect the board for visible signs of damage: burnt components, discolored areas, leaking or swollen capacitors, loose connections, and corrosion. They also check diagnostic indicators and error codes to identify potential faults and narrow down the cause.

3. Electrical Testing & Fault Diagnosis

Using the right diagnostic equipment, technicians check voltage levels, electrical connections, and signal paths to confirm whether the board is working correctly. Depending on the issue and the control system, they may test individual components such as relays, diodes, and transistors. These checks help separate a control board fault from a problem elsewhere in the elevator system.

4. Component-Level Repair or Control Board Replacement

Once technicians identify the source of the problem, they determine whether the board can be repaired or must be replaced.

  • Component-level repair: If the damage is limited to specific parts or connections, technicians may replace faulty components, repair damaged solder joints, or address other localized issues, provided the repair is supported by the manufacturer’s specifications.
  • Control board replacement: If the board is extensively damaged or cannot be reliably repaired, replacement may be necessary. The replacement board must be compatible with the elevator’s control system and may require configuration or programming per the manufacturer’s requirements.

5. System Testing & Verification

After the repair or replacement, technicians confirm the board communicates properly with the elevator’s other components. They perform the necessary operational and safety checks, which may include testing door interlocks, emergency stops, limit switches, floor leveling, and other relevant functions. The elevator should only be returned to service once those checks confirm it meets applicable safety and operational requirements

Repair, Replace, or Modernize: Which Is the Better Option?

When an elevator control board fails, repairing it isn’t always the only option. Depending on the extent of the damage, parts availability, and the condition of the existing system, replacing the board or considering a broader modernization may make more sense. Here’s what to weigh before deciding:

  • Repairing the existing board is often a practical choice when the problem is isolated, replacement components are available, and the rest of the elevator system is in good working condition. If a technician can reliably repair the damaged board, there may be little reason to replace a larger part of the system.
  • Replacing the control board may be necessary when the damage is extensive, the board cannot be reliably repaired, or a compatible replacement is available. On its own, though, replacement may not solve recurring problems caused by aging equipment or other components in the control system.
  • Modernizing the elevator may be worth considering when board failures become frequent, compatible replacement parts get harder to source, or the existing control system is approaching the end of its useful life. One factor to weigh here is whether the elevator uses proprietary or non-proprietary equipment.

Some elevators use proprietary control boards, which can limit access to replacement parts and qualified service providers. Depending on the manufacturer, building owners may have fewer options when sourcing components or arranging repairs. Non-proprietary systems generally offer more flexibility because multiple providers may offer compatible parts and service.

If an aging proprietary system becomes difficult or expensive to maintain, modernizing to a non-proprietary elevator system may offer greater long-term flexibility. Chicago Elevator’s modernization and upgrade services can help building owners explore their options based on the condition and requirements of their existing equipment.

How to Prevent Elevator Control Board Failure

Not every control board failure can be prevented, but proper maintenance and a suitable operating environment can reduce the risk of premature damage. Building owners can take a few steps to protect control boards and help keep their elevators running reliably.

  • Keep the machine room clean and properly ventilated. Excessive heat, dust, and moisture can affect electronic components and contribute to premature wear. Keep the machine room within the temperature and environmental limits specified by the elevator manufacturer. Regular cleaning and adequate ventilation also help prevent dust buildup around the equipment.
  • Protect the elevator’s electrical supply. Power surges, voltage fluctuations, and other electrical disturbances can damage sensitive control board components. Have a qualified elevator technician or electrical professional assess the power supply and determine whether surge protection and other safeguards are needed.
  • Schedule regular elevator maintenance. Routine inspections give technicians a chance to catch potential problems before they turn into bigger ones. They can check for loose connections, signs of overheating, damaged components, recurring error codes, and other irregularities that point to a board issue or a wider electrical problem.

A consistent preventive elevator maintenance schedule helps identify developing issues early, reduces unexpected breakdowns, and extends the service life of elevator components. It also gives technicians a chance to address small problems before they cause a bigger interruption.

Get a Clear Answer on Your Elevator Control Board

As the brain of an elevator, and like any electronics, the control board is vulnerable to heat, power, and age. The good news is that most failures are either repairable at the component level or preventable with regular maintenance. And when a board truly reaches the end of its life, modernization is a chance to upgrade to something more reliable and easier to service.

Seeing error codes or an elevator that won’t level out? It may be your control board. Chicago Elevator can diagnose the problem honestly and tell you whether a repair, replacement, or modernization makes the most sense for your building, with no guesswork and no pressure. Contact our team to get started.

iStock 1442664779

Elevator Accident Statistics & Common Accidents Every Building Owner Should Know

Elevators are designed to move people safely and efficiently, but like any mechanical system, they can become dangerous when equipment fails, maintenance is neglected, or safety procedures aren’t followed.

For building owners, understanding elevator accident statistics, common causes, and prevention strategies can help reduce risk, protect occupants, and keep elevator systems operating safely.

In this guide, we’ll look at the numbers every building owner should know, and what they mean for your property.

Key Elevator Accident Statistics at a Glance

How common are elevator accidents? While no single data set captures every incident nationwide, the following statistics provide a useful picture of the general risks to consider.

26,158 Elevator and Lift Injuries in One Year

The U.S. Consumer Product Safety Commission (CPSC) National Electronic Injury Surveillance System (NEISS) 2023 data* estimated just over 26,000 injuries associated with elevators and other lifts treated in hospital emergency departments. That works out to approximately 7.8 injuries per 100,000 residents.

For building owners, these elevator injury statistics offer a reminder that even everyday equipment needs consistent attention.

*Important: This CPSC category includes “Elevators, Other Lifts,” so the number does not represent passenger elevators alone. 

856 Cases in the CPSC Sample

The same 2023 NEISS data recorded 856 actual injury cases involving elevators and other lifts across its sampled hospitals, but that number is not the total number of elevator injuries nationwide. NEISS assigns statistical weights to reported cases to produce the larger national estimate.

The sample count and national estimate measure related, but different, things, and neither represents the actual number of elevator accidents per ride.

Elevator Worker Safety

CPSC’s NEISS system is a nationally representative injury-surveillance system that uses emergency-department data to produce nationwide estimates, but these numbers are not the only elevator safety statistics worth looking at.

A 2019 research report from CPWR, archived by the CDC, found 145 fatalities between 2011 and 2016 among construction workers in the U.S. due to elevator-related injuries. Falls to a lower level accounted for 53.5% of those fatalities during that period.

What this means for building owners

These statistics highlight two distinct areas of elevator safety: protecting passengers during everyday use and protecting workers who install, inspect, and service equipment.

Elevator accidents may represent only a small fraction of the millions of elevator trips made every day, but an individual incident can have serious consequences.

6 Common Elevator Accidents Building Owners Should Be Aware of

Not every elevator accident happens because an elevator suddenly falls. Many incidents involve doors, falls, leveling problems, equipment failures, or maintenance activities.

1. Elevator Door Accidents

Elevator doors open and close countless times in busy buildings. Potential hazards include:

  • Doors closing on passengers
  • Malfunctioning door sensors
  • Doors failing to reopen
  • People becoming caught between doors
  • Hoistway doors opening when the elevator is not present
  • Damaged or improperly adjusted door equipment

For building owners, elevator door problems should never be treated as a minor inconvenience.

2. Trips and Falls

Passengers can lose their balance while entering or exiting an elevator, particularly when the elevator car does not stop level with the floor. Even a relatively small difference between the elevator floor and building floor can create a hazard, particularly for:

  • Older adults
  • People with mobility limitations
  • People carrying objects
  • Children
  • Anyone using a wheelchair or mobility device

3. Elevator Shaft Falls

Open elevator shafts present an extremely serious hazard, particularly during construction, installation, and maintenance work.

A person can fall into a shaft if:

  • A landing door is left open
  • A protective barrier is missing or damaged
  • An elevator is taken out of service improperly
  • Maintenance work creates an unprotected opening
  • Safety interlocks are bypassed

OSHA requires appropriate protection at elevator landing openings in the workplaces covered by its standard.

4. Elevator Entrapment

Passengers can become trapped inside an elevator because of:

  • Power failures
  • Mechanical problems
  • Controller failures
  • Door problems
  • Safety-system activation
  • Equipment breakdowns

An entrapment does not automatically mean someone has been injured. However, attempting to force the doors open or exit a car that is not level with a landing can create serious danger. Building staff should know how to communicate with trapped passengers and contact qualified emergency responders rather than attempting an unauthorized rescue.

5. Crushing & Caught-Between Accidents

Maintenance personnel face hazards that passengers typically do not encounter. These include being:

  • Caught between moving equipment
  • Crushed between the elevator car and shaft
  • Struck by moving components
  • Trapped in an elevator pit
  • Injured while working on top of the elevator car

Such incidents underscore the importance of controlling equipment movement and following proper safety procedures during service. OSHA accident investigations have documented fatal incidents involving elevator pits and maintenance work.

6. Elevator Maintenance Accidents

Elevator technicians work around powerful mechanical, electrical, and moving systems. Potential hazards include:

  • Electrical exposure
  • Unexpected elevator movement
  • Falls
  • Moving machinery
  • Hoistway hazards
  • Improper lockout/tagout
  • Bypassed safety devices

OSHA warns that machinery can cause severe injuries when hazardous energy is not properly controlled during servicing.

For building owners, elevator maintenance safety starts with choosing qualified professionals and ensuring untrained building staff do not attempt repairs.

What Causes Elevator Accidents?

Elevator accident causes vary depending on the equipment, operating conditions, and activities taking place when an incident occurs. Not every accident results from equipment failure. However, knowing common causes of elevator accidents can help you spot problems that need professional attention.

Poor or Inadequate Maintenance

Elevators contain mechanical and electrical components that need regular inspection, adjustment, and servicing. When maintenance is delayed, problems such as worn door parts, faulty sensors, or inconsistent leveling can go unnoticed.

A consistent preventive maintenance program helps identify developing problems and address them before they lead to more serious failures.

Worn Elevator Components

Frequent use stresses elevator doors, rollers, bearings, braking components, and other moving parts. As components wear, an elevator may become noisier, operate less smoothly, or experience repeated service interruptions.

Routine inspection and timely replacement of deteriorating parts help maintain reliable operation.

Electrical Problems

Elevators rely on controllers, wiring, sensors, switches, and electrical safety circuits. Faults in these systems can affect door operation, leveling, communication, or overall operation.

Qualified technicians should diagnose electrical problems. Building staff should never attempt to bypass an electrical fault simply to restore service.

Door & Interlock Problems

Elevator doors have safety mechanisms designed to prevent unsafe operation. Door interlocks help prevent an elevator from operating when landing doors are not properly secured. Sensors and reopening devices help protect passengers while they enter or exit.

When these components fail or fall out of adjustment, they can create safety hazards and repeated shutdowns. OSHA specifically requires that elevator safety devices should not be overridden or made inoperable.

Improper Repairs

Incorrect adjustments, unsuitable replacement parts, and incomplete repairs can introduce new equipment problems. Elevator work requires specialized knowledge, particularly when dealing with door safety circuits, brakes, controls, and emergency systems.

Appropriately licensed or qualified elevator professionals should perform repairs, with required testing completed before the equipment returns to service.

Aging or Obsolete Equipment

Older elevators are not automatically unsafe. However, aging systems may need more frequent repairs, and some replacement components can become difficult to obtain.

When breakdowns become recurring, or the equipment no longer meets applicable requirements, elevator modernization may be the more practical long-term solution.

Human Error

Some elevator accidents involve unsafe actions rather than mechanical defects. Examples include forcing open elevator doors, entering a shaft without proper precautions, overriding safety devices, or attempting repairs without the necessary training.

Clear building procedures and qualified service personnel are key to preventing elevator accidents.

How Building Owners in Chicago Can Prevent Elevator Accidents

The best way to reduce elevator risk is to focus on prevention rather than emergency repairs.

1. Schedule Preventive Maintenance

One of the most effective elevator maintenance best practices is servicing equipment before it fails. A preventive maintenance program should account for the elevator’s age, design, traffic level, and condition. Service visits may include inspecting door operators, checking leveling accuracy, testing safety devices, and examining mechanical and electrical components.

Chicago Elevator offers elevator maintenance services tailored to each building’s equipment and operating needs.

2. Complete Required Inspections

In Chicago, the City’s Annual Inspection Certification program requires building owners and property managers to arrange annual inspections by state-licensed, third-party inspection companies. Results must be submitted to the Department of Buildings through the AIC portal. Additional testing and compliance requirements may also apply depending on the equipment and jurisdiction.

A service provider familiar with elevator code compliance and violation removal can help you address deficiencies and prepare for required inspections.

3. Address Problems Immediately

Don’t ignore reports such as:

  • “The elevator is shaking.”
  • “The doors aren’t closing correctly.”
  • “The elevator stopped between floors.”
  • “The elevator isn’t level with the floor.”
  • “There’s a strange noise.”
  • “The elevator keeps going out of service.”

Small operating issues can indicate larger mechanical or electrical problems. Prompt repairs can reduce the risk of further damage and help prevent avoidable service interruptions.

4. Never Disable Safety Devices

Elevator safety devices serve important functions, from keeping landing doors secured to detecting unsafe operating conditions. Never allow staff to bypass door interlocks, disable protective devices, or override safety controls to keep an elevator running.

Any necessary testing or adjustment of these systems must be performed by qualified personnel following applicable safety procedures.

5. Keep Elevator Areas Secure

Restrict access to:

  • Machine rooms
  • Elevator pits
  • Hoistways
  • Control equipment
  • Other service areas

Only trained and authorized personnel should perform elevator maintenance or repairs. Coordinate with the service team to protect areas where workers or building occupants might encounter hazards.

6. Keep Detailed Maintenance Records

Documenting maintenance is an important part of elevator safety for building owners. It should include:

  • Inspections
  • Repairs
  • Preventive maintenance
  • Replaced components
  • Testing
  • Service calls
  • Recurring problems
  • Modernization work

A clear maintenance history helps technicians spot recurring issues and lets you track your equipment’s condition. This is why a structured elevator maintenance agreement always includes keeping service visits and documentation consistent.

Protect Your Building With Professional Elevator Service

Elevator accident statistics show why ongoing maintenance, timely repairs, and required inspections matter. While every incident is different, many equipment-related hazards can be identified and addressed before they become bigger problems.

Staying on top of elevator safety also means understanding the requirements that apply to your property.  Whether you are dealing with recurring breakdowns, preparing for an inspection, or reviewing an aging elevator system, our team can help you understand what needs attention, including the common violations to avoid.

Don’t wait for an elevator accident to reveal a problem that could have been addressed earlier. Contact our team to discuss your equipment and schedule a professional service assessment.

AdobeStock 298201035

How Elevator Downtime Impacts Tenant Experience & Property Value

How Elevator Downtime Impacts Tenant Experience & Property Value

Picture a Monday morning in your building. The lobby is busy, people are heading to work, and the elevator is dark with an “out of service” sign taped to the door. Within the hour, your phone is ringing. Tenants are frustrated, your property manager is fielding complaints, and someone wants to know when it will be fixed.

Elevator downtime is more than an inconvenience. It costs you money, strains your relationship with your tenants, and over time can chip away at your property’s value. Here is what is really at stake, and what you can do to keep it from happening.

What Elevator Downtime Really Costs a Building

Elevator downtime is any stretch of time when your elevator is out of service and unavailable to the people who need it. Sometimes it is a quick fix. Other times a part has to be ordered, and the car sits idle for days.

The cost shows up in the two places that matter most to any owner or manager:

  • Tenant experience: The daily frustration your residents or office workers feel when they can’t rely on the elevator.
  • Property value: The longer-term hit to your building’s income, reputation, and resale potential.

Let’s look at both in more detail.

How Downtime Affects Tenant Experience

For your tenants, a working elevator is not a perk. It is a basic expectation, like running water or heat. When it stops, their day stops with it.

Who Actually Depends on the Elevator

It is easy to underestimate how many people have no good alternative when the car goes down:

  • Older residents and anyone with a disability
  • Parents with strollers
  • Delivery workers and movers
  • Anyone carrying something heavy or making a quick trip between floors

For many, the stairs are not a real option. A single broken elevator can cut tenants off from their own homes or offices. That is a serious accessibility problem, and in some cases a compliance one.

Complaints and Tenant Retention

Every hour an elevator is down, your management team is answering calls instead of doing their job. Tenants start to wonder whether the building is being looked after.  And when a lease comes up for renewal, those memories matter.

Reliability is one of the quietest reasons tenants stay, and one of the loudest reasons they leave.

How Downtime Affects Property Value

Tenant frustration eventually shows up as a number on your books in the following ways:

Vacancy and Turnover

When good tenants leave, you face vacancy, turnover costs, and the expense of getting a unit ready for someone new. Those costs add up fast, and they trace straight back to whether your building runs the way people expect it to.

What Buyers and Lenders See

A property with a history of elevator problems and emergency repairs raises red flags. It signals deferred maintenance and unpredictable costs, and that affects both the sale price and how the building gets financed. 

A well-maintained elevator with clean service records does the opposite; it tells people the building has been cared for.

The Hidden Cost of Emergency Repairs

Here is a cost that catches a lot of owners off guard: emergency repairs almost always cost more than planned ones. When an elevator fails without warning, you pay for rushed labor, expedited parts, and however much downtime it takes to get running again. 

Planned maintenance is cheaper and predictable, which makes budgeting much easier.

Why Elevators Go Down in the First Place

Most elevator failures are not sudden; they build up over time. The usual causes are:

  • Deferred maintenance that lets small problems grow
  • Aging parts that were never replaced on schedule
  • A service approach that only reacts to problems instead of catching them early

This pattern is especially common in older buildings, where elevators tend to break down repeatedly when equipment hasn’t kept pace with its age.

An elevator is a machine with many moving parts, and like any machine, small issues grow into big ones when no one watches for them. A worn component that could have been swapped during a routine visit can become the reason your elevator sits idle a month later.

Elevator Inspection Rules in Chicago & What They Mean for You

Downtime isn’t only a service issue. In Chicago, keeping your elevator running is tied directly to staying compliant with the city, and falling behind on either one can put you in a bad spot.

Chicago’s Annual Inspection Requirement

The City of Chicago requires elevators in commercial and multi-tenant buildings to be inspected every year. The city runs this through its Annual Inspection Certification (AIC) program, and the basics look like this:

  • You hire an Illinois-licensed, third-party inspection company to inspect your elevators each year.
  • The company files the results electronically with the Department of Buildings.
  • A certificate of inspection is posted in the elevator car once all of your building’s elevators pass.

Beyond the annual inspection, elevators also require periodic safety tests on longer cycles, which your service provider should track so nothing slips through.

Who Is Responsible

The responsibility sits with the building owner, not the tenant and not the city. If an inspection finds a problem, you must correct it and keep your certificate current. Let that lapse, and you can end up with an elevator pulled out of service and a certificate you have to work to get reinstated.

A good service partner keeps you ahead of these dates and handles code compliance and violation removal before small issues become formal violations.

Northwest Indiana and the Suburbs

Requirements are not the same everywhere. The Chicago suburbs and Northwest Indiana fall under different jurisdictions, each with its own inspection rules and timelines. This is one real advantage of working with a service company that knows your specific market. The right partner knows which rules apply to your building and keeps you compliant without you having to chase down the details yourself.

How to Reduce Elevator Downtime

The good news is that most downtime is preventable. It comes down to three things:

1. Preventive Maintenance

Regular, scheduled visits let a technician catch worn parts and small problems before they take the elevator out of service. This is the single most effective way to keep your elevators running and your repair costs down.

Start here: preventive maintenance does more to minimize downtime than anything else on this list. 

2. Real Maintenance Contract

Not every agreement is the same. A good elevator maintenance contract spells out:

  • How often your elevators are serviced
  • What is covered
  • How quickly someone shows up when something goes wrong

If you are not sure how to compare them, it helps to know what to look for in a maintenance agreement before you sign. Response time matters. When your elevator is down, you want to know help is on the way, not wonder when someone will call you back.

3. Modernization at the Right Time

At some point, aging equipment costs more to patch than to update. If you are repairing the same system over and over, modernization can improve elevator reliability, safety, and energy efficiency, and it often pays for itself in fewer breakdowns and lower operating costs.

What to Expect from a Dependable Elevator Service Partner

Good commercial elevator maintenance is not complicated, but it is rare to find it done well. You should expect:

  • Clear communication, so you always know the status of your equipment
  • A fast response when something goes wrong
  • Honest, transparent reporting, so you can see exactly what was done and why

That is the standard we hold ourselves to at Chicago Elevator Company. We stay personally involved in the work, we keep you informed, and we stand behind what we do. For building owners and managers across Chicago and Northwest Indiana, that means fewer surprises and elevators you can count on.

Keep Your Building Running

Elevator downtime is one of those costs that stays hidden until it isn’t. It frustrates your tenants, eats into your budget, and quietly undermines your building’s value. The fix is not complicated. It is consistent, preventive care from a service company that communicates clearly and shows up when you need them.

Tired of surprise breakdowns and scrambling for repairs? A preventive maintenance plan keeps your elevators running and your tenants happy. Contact Chicago Elevator for a straightforward assessment of your building’s service needs. We’ll tell you exactly where you stand.

AdobeStock 612232365

Elevator Phone Options: What Building Owners Need to Know

Every commercial elevator has a phone, but few building owners think about it until it matters. For most, there are two things worth understanding here, the equipment inside the cab and the line that connects it to a live person on the other end. 

In Chicago and Northwest Indiana, the requirements depend on which elevator code applies to your building, and the ongoing retirement of traditional copper phone lines is pushing many owners to reconsider how that connection is set up.

Why Does an Elevator Need a Phone?

An elevator phone allows a passenger to contact help without relying on their personal cell phone. Elevator cabs can have limited or no cellular reception, and a passenger may not have a working phone available when an elevator stops.

The emergency communication system is part of the elevator’s required safety equipment. It works alongside other systems, including the elevator service key, to help building personnel and emergency responders handle elevator-related emergencies.

What Are the Elevator Phone Requirements?

In Chicago and throughout Illinois, elevator emergency phones must meet the applicable elevator safety and building code requirements. Illinois has adopted ASME A17.1 as its elevator safety code, enforced by the Illinois Office of the State Fire Marshal, while the City of Chicago enforces its own requirements through the Department of Buildings’ Elevator Bureau.

An elevator’s emergency communication system generally needs to provide:

  • Two-way communication – Passengers must be able to communicate with someone who can respond to an emergency and arrange assistance.
  • 24-hour response – The emergency call must reach someone who can respond around the clock, whether that is on-site staff or a monitoring service.
  • Location identification – The person receiving the call needs to be able to identify the building and elevator where the call originated.
  • Reliable operation – The system must remain available when passengers need assistance, including during a building power outage.

The requirements for an existing elevator can differ from those for a new installation or modernization. An older elevator is not automatically required to meet every requirement in the newest code edition, and the applicable requirements depend on the code in effect for the elevator and whether it is being repaired or undergoing a modernization project.

What Are Your Elevator Phone Line Options?

The emergency phone inside the cab needs a reliable connection outside the elevator. For many older buildings, that connection has traditionally been a copper phone line. As telephone providers move away from traditional copper service, building owners may need to consider other options.

Traditional Copper Landline (POTS)

POTS, or Plain Old Telephone Service, is the traditional copper phone line that has connected elevator emergency phones for decades. Its main advantage is that the phone company powers the line, so it keeps working during a building power outage.

The challenge is availability. Providers are moving away from copper networks, and keeping an existing line may become more expensive or difficult as those networks are retired.

Cellular Line

A cellular unit installed for the elevator connects through a wireless network instead of a physical phone line. These systems typically include battery backup and do not depend on the building’s internet. The main things to confirm are adequate cellular coverage where the equipment is located and an active service plan.

VoIP or Digital Line

VoIP sends calls over an internet connection. It can work for elevator communication when the system is designed for that purpose, but a standard office VoIP service is not the same. Because an internet or power outage can interrupt a conventional setup, an elevator application needs appropriate backup power and equipment.

Why Do Elevator Phones Stop Working?

Since elevator phones are rarely used day to day, problems can go unnoticed for a while. A few common causes are worth knowing about:

  • The phone line was disconnected – This is becoming more common as carriers retire copper lines, sometimes with limited notice.
  • The phone equipment wore out – Handsets and auto-dialers do not last forever, and an older unit may eventually stop completing calls.
  • The wiring deteriorated – Wiring between the cab and the phone connection is exposed to constant movement and vibration, and it can degrade over time.
  • The monitoring service lapsed – If the phone dials a monitoring service and that contract has ended, the call may reach a number that is no longer answered.

Many newer systems monitor the phone line and signal a problem if it goes down. Older setups may give no such warning, which is one reason a phone can sit unnoticed until an inspection or an emergency.

Who Answers the Elevator Phone?

The elevator phone needs to reach someone who can respond to an emergency at any time. Buildings generally handle this through on-site personnel or an elevator monitoring service.

  • In-house staff – Some buildings have personnel available around the clock who can answer emergency calls and arrange assistance. Some elevator installations may also require on-site personnel, depending on the building and elevator.
  • Monitoring service – A third-party monitoring service can receive elevator emergency calls and have trained operators respond. The operator can confirm the location and situation and arrange the appropriate assistance.

An emergency phone that simply rings to an answering machine or an unattended number does not provide the response the system is intended to provide.

How Can You Check Your Elevator Phone’s Compliance?

Building owners can start with asking themselves a few basic questions:

  • Does the emergency phone connect to a live person 24/7?
  • Can the person receiving the call identify the building and elevator?
  • Does the phone have adequate backup power?
  • Is the elevator still using a copper phone line?
  • If the elevator is new or has been modernized, does its communication system meet the requirements that apply to the installation?

There is also a simple test you can do yourself. Go to each elevator, pick up the phone or press the emergency call button, and confirm that the call reaches a live person and that you can both hear each other clearly. If your building has more than one elevator, keep in mind that each cab needs its own working phone and connection, so check every car rather than assuming they all behave the same.

Elevator inspections generally include testing the emergency phone. Many building owners also have it checked as part of regular elevator maintenance, and testing it periodically rather than waiting for the annual inspection helps catch a problem early.

Keep Your Elevator Phone Compliant & Ready

Elevator emergency phones need to work when passengers need them, including during situations where building power or regular communication systems may not be available.

For buildings with older phone systems, the transition away from traditional copper service is another reason to review the existing setup. A contractor can determine what type of phone connection the elevator currently uses, check the communication equipment, and explain available replacement options.

Keeping your elevator phone system current is part of maintaining a safe, compliant elevator. If you need help with your elevator or related equipment, our experienced team at Chicago Elevator works with building owners on a range of elevator services. Reach out to us for personalized guidance.

iStock 1214579071

What Is an Elevator Service Key & Who Should Have Access to One?

An elevator service key may look like a simple key, but it provides access to specific elevator functions that aren’t available during normal passenger operation. For building owners and property managers, knowing what an elevator service key is used for, who should have access to it, and where to keep it can help support safe elevator operation.

In Chicago and throughout Illinois, elevator service keys can be especially important when an elevator must be operated outside normal passenger service. Understanding what these keys are and how they are used can help building managers know when they may be needed and who should handle them.

What Is an Elevator Service Key?

An elevator service key is used to operate a keyed switch or control associated with an elevator’s specialized functions. Unlike the buttons passengers use to select floors, keyed controls can provide access to functions intended for authorized personnel. 

The exact key and function depend on the elevator equipment; a key that operates one function on an elevator may not operate another. For that reason, elevator service keys shouldn’t be treated as general-purpose keys for anyone who works in the building.

What Is the Purpose of an Elevator Service Key?

An elevator service key allows authorized personnel to access specific elevator controls that aren’t available during normal passenger operation. These controls can be used when an elevator needs to be operated, inspected, or serviced outside of its normal use.

Depending on the elevator system, an elevator service key may be used for:

  • Emergency operation when firefighters need to operate the elevator during an emergency
  • Maintenance and service when elevator technicians need to access specialized controls
  • Inspection and testing when authorized personnel need to check specific elevator functions
  • Other specialized operations depending on the elevator’s equipment and configuration

The specific functions controlled by an elevator service key can vary by elevator. Building owners and property managers should work with their elevator contractor to identify the keys used for their equipment and understand what each one controls.

Who Should Operate an Elevator Service Key?

Only authorized personnel trained or licensed to use the function it controls should operate an elevator service key. The person using the key will depend on the situation and the type of elevator service or emergency operation involved.

Firefighters

Firefighters may use the appropriate fire service key to operate an elevator equipped with Firefighters’ Emergency Operation during an emergency. The key allows them to access the elevator’s designated fire service controls and operate the elevator according to the building’s emergency procedures.

Elevator Mechanics & Contractors

Licensed elevator mechanics and contractors may use elevator service keys when performing maintenance, repairs, testing, or other authorized work. These keys provide access to specialized elevator controls not intended for normal passenger use.

Elevator Inspectors

Licensed elevator inspectors may operate the appropriate elevator controls when performing required inspections and tests. Access to the necessary controls allows inspectors to verify that the elevator and its safety functions operate as required.

How Is an Elevator Service Key Used During Fire Service?

One of the most important applications of an elevator key is Firefighters’ Emergency Operation. Fire service operation allows an elevator to be removed from normal passenger operation and used according to emergency procedures.

Phase I Emergency recall

Phase I recalls the elevator to a designated landing after the appropriate fire alarm initiating device is activated. The elevator is then removed from normal passenger service so it can be used as part of the building’s emergency response procedures.

Phase II Emergency In-Car Operation

Phase II allows firefighters to operate the elevator from inside the elevator car using the fire service controls. Chicago’s fire service testing guidance calls for a monthly Phase I recall test using the key switch and at least one floor of Phase II firefighters’ emergency service operation. The test results are recorded in a fire service test log.

The fire service key therefore isn’t simply a spare key for the elevator. It is part of the controls used for emergency elevator operation.

Where Should an Elevator Service Key Be Kept?

Fire service keys should be kept in a secure, approved location that authorized emergency personnel can access quickly, such as a lockbox or a designated spot known to the fire department and building staff. 

The building owner, property manager, or elevator contractor typically controls other service or maintenance keys and stores them separately from fire service keys.

In Chicago, fire service equipment and key access are part of elevator maintenance and inspection requirements. Chicago building inspection records, for example, can identify missing FEOK1 keys and unsecured fire service boxes as elevator-related deficiencies.

Building managers should know:

  • Which elevator keys their equipment requires
  • What each key is used for
  • Where the required keys are stored
  • Who has authorized access
  • Whether the keys and related fire service equipment are in the condition required for the building

If you’re unsure where an elevator service key should be kept, your elevator contractor can help identify the appropriate key and storage requirements for the equipment.

Are Elevator Service Keys Universal?

No, elevator service keys are not universally interchangeable. Different elevator functions can use different keys, and the required key can depend on the elevator equipment, manufacturer, installation, and applicable code requirements.

Fire service keys may be standardized for particular applications, but that doesn’t mean every elevator service key is the same. For example, a fire service key shouldn’t automatically be assumed to operate a maintenance or inspection control. Similarly, a key used for one elevator may not operate the same function on another elevator.

If you need a replacement or additional key, it’s better to identify the elevator and the specific keyed control before ordering or duplicating one.

Why Is Elevator Service Key Access Important?

An elevator service key provides access to specialized elevator controls not intended for normal passenger use. For that reason, building managers should know which keys are used for their elevators, where they are kept, and who is authorized to use them.

Proper key access helps ensure that:

  • Authorized personnel can access the controls they need
  • Fire service keys are available when emergency operation is required
  • Untrained individuals do not operate specialized elevator controls
  • Maintenance and inspection personnel can access the equipment when needed
  • Lost or duplicate keys can be identified and addressed

The key should be accessible to the right people without being freely available to anyone in the building. Building managers should coordinate with their elevator contractor if they are unsure about which service keys their equipment requires or how those keys should be managed.

The Role of Elevator Service Keys in Maintenance & Inspection

Elevator service keys can be used by authorized elevator personnel when accessing or testing specialized elevator functions. During a maintenance or inspection visit, an elevator mechanic or inspector may need to operate keyed controls as part of the work.

Illinois requires elevator work to be performed by appropriately licensed personnel under the Elevator Safety and Regulation Act, which is administered by the Illinois Office of the State Fire Marshal.

Building owners and property managers must ensure the elevator is properly maintained and that qualified personnel have the access they need to perform required work.

What Happens If an Elevator Service Key Is Missing?

A missing key can become a problem when authorized personnel need access to a specialized elevator function. For example, a missing fire service key could complicate required fire service operation or testing. A missing maintenance or service key could delay work that requires access to a keyed control.

If a key is missing, building personnel should contact their elevator contractor rather than bypassing a keyed control or using an unverified replacement. The elevator contractor can identify the correct key and determine whether the key, switch, or related equipment needs service.

Keep Your Elevator Service Keys Ready for When They’re Needed

An elevator service key can provide access to functions that matter during emergency response, maintenance, inspection, and testing.

For building owners and property managers, the important questions aren’t just where the key is. It’s also which key the elevator requires, what it operates, who should have access to it, and whether the elevator’s required fire service testing is up to date.

Have questions about your elevator service key or fire service operation? Chicago Elevator can help you identify the equipment in your building and provide the maintenance and testing services needed to keep your elevator in proper working condition. Contact Chicago Elevator to get started.

iStock 1303998247

Elevator Door Problems: Why They Happen & When to Repair

If you own or manage a building, elevator door problems are hard to miss. The doors may start moving more slowly, make unusual sounds, reopen when no one is in the doorway, or stop closing properly.

Elevator doors are among the most frequently used parts of an elevator system, particularly in busy Chicago office buildings and apartment buildings. Over time, that constant use can wear down door operators, rollers, tracks, sensors, and other components.

Knowing the signs of a door problem can help you address it before it leads to a service interruption. Here are some of the most common elevator door problems, what causes them, and when professional repair is needed:

Why Elevator Door Problems Shouldn’t Be Ignored

It’s tempting to treat a sticky or slow door as a minor annoyance, but door issues are worth taking seriously for a few reasons:

  • Safety – Elevator doors have sensors and safety systems designed to keep people from getting struck or caught. When those systems start misbehaving, safety is the first thing at risk.
  • Downtime – A door that won’t close will take the entire elevator out of service. In a building with one or two units, that’s a major disruption for tenants.
  • Tenant frustration – Nothing generates complaints faster than an unreliable elevator. Door problems are the issue tenants notice most.
  • Code compliance – In Illinois, elevators are inspected and must meet safety codes. Door problems are a common reason a unit fails inspection.

In short, a door problem is rarely just a door problem. It’s usually the first sign that something needs attention.

Explore the elevator modernization trends and upgrades for 2026

6 Common Elevator Door Problems & What They Mean

Most elevator door issues fall into a handful of recognizable patterns. Knowing what each one looks like, and what it’s likely telling you, makes it easier to describe the problem, judge how urgent it is, and have a straight conversation with your service company. Here are six of the most common elevator door problems we get called out for, and what each one usually means:

1. The doors won’t open or close

Doors that won’t open or close properly can have several causes. A sensor may not be reading correctly, something may be obstructing the door, or the door operator may have a mechanical or electrical problem. If the doors stay open, stop partway, or stop responding altogether, the elevator usually needs to be taken out of service until a technician can inspect it. This is one to address quickly, since it directly affects whether people can get in and out.

2. The doors open or close slowly

Doors that move slower than usual are often an early warning sign. As the door operator, tracks, rollers, and other moving parts wear over time, the door loses the smooth, consistent motion it had when it was new. The change can be gradual and easy to overlook in a busy building, but paying attention to it lets you catch a small problem before it becomes a bigger service issue.

3. The doors keep reopening

Elevator doors are designed to reopen when a sensor or safety device detects an obstruction. If the doors reopen repeatedly when nothing is blocking them, there may be a problem with the sensors or another part of the door system. Repeated reopening also delays passengers and puts extra wear on the door equipment. A technician can tell whether the system needs adjustment, repair, or a worn component replaced.

4. The doors are stuck

A stuck door can keep passengers from entering or exiting and often leaves the elevator out of service. The cause could be the door operator, tracks, rollers, alignment, or another mechanical component. Forcing the doors open or closed can make the problem worse and should be avoided. This is best left to a technician.

5. The doors are misaligned

Doors should meet evenly and move smoothly during normal operation. If they look uneven, drag against each other, or don’t line up correctly when closing, the door system likely needs adjustment or repair. Alignment problems tend to develop as components wear or become damaged, and left unresolved, they can put strain on other parts of the door system.

6. The doors make unusual noises

Grinding, scraping, rattling, or other new sounds usually signal that something in the door system needs attention. It’s easy to dismiss these as normal elevator noise, but they often point to worn rollers, misalignment, or debris in the track. A technician can inspect the door components, find the source, and determine whether maintenance or repair is needed before the problem grows.

What Causes Elevator Door Problems?

Several issues can contribute to elevator door problems, including:

  • Normal wear and tear: Frequent operation gradually wears down moving components.
  • Worn or damaged components: Rollers, tracks, operators, and other parts can affect door movement when they deteriorate.
  • Sensor problems: Faulty or misaligned sensors can cause doors to reopen or prevent them from closing properly.
  • Alignment issues: Misaligned doors or tracks can cause sticking, dragging, or uneven movement.
  • Obstructions: Objects or debris in the door track can interfere with normal operation.
  • Door operator problems: A malfunctioning operator can affect how quickly and smoothly doors open and close.
  • Lock or interlock problems: Issues with door locks and interlocks can prevent the elevator from operating as intended.
  • General age: On older equipment, door problems often reflect a system that’s reaching the end of its service life, which is one reason elevators in older buildings tend to need repairs more often.

Finding the underlying cause is important because repeatedly resetting the elevator without addressing the problem can allow the same issue to return.

When Should Elevator Doors Be Repaired?

Not every change means a major repair, and a single slow cycle or odd noise usually isn’t cause for alarm. What matters is the pattern. Some door problems need attention right away, while others can be scheduled before they turn into something bigger.

Call for repair right away when:

  • The doors won’t open or close
  • A door is creating any kind of safety concern
  • A door problem is taking the elevator out of service

When people’s ability to safely get in and out is in question, it’s not worth waiting on. A professional should inspect the elevator before it goes back into normal use.

Schedule a repair soon when you notice:

  • The same door issue keeps returning after it’s been reset or cleared
  • A problem is happening more often than it used to
  • Several elevators start showing the same door issue around the same time
  • The equipment needs adjusting again and again without the fix holding

Handling them early is almost always cheaper and less disruptive than waiting for a full failure. It also helps to know how long an elevator repair usually takes and what can delay it so you can plan around the downtime.

Why Door Problems Shouldn’t Wait

Since elevator doors are directly tied to rider safety, a door problem isn’t one to let slide. Beyond safety, door and door-lock faults are among the most common reasons elevators fail inspections, and a downed elevator can become an expensive emergency when it finally gives out at the worst possible time.

Addressing door problems early is almost always cheaper, safer, and less disruptive than waiting for a full failure. Regular preventive maintenance, where a technician inspects and services the doors before they fail, is the single best way to keep small issues from becoming big ones.

And if a repair is needed, it helps to know how long an elevator repair usually takes and what can delay it, so you can plan around the downtime.

Keep Elevator Door Problems From Becoming Bigger Repairs

Elevator door problems rarely fix themselves. A door that is slow, noisy, misaligned, or repeatedly reopening is worth having checked, especially when the problem becomes more frequent or affects service.

Regular maintenance and timely repairs can help keep the door system working properly and reduce the chance of an unexpected shutdown. If you’re seeing signs that something isn’t right, having the problem diagnosed early can save you from a more disruptive repair later.

Need help with an elevator door problem? Chicago Elevator provides elevator repair and maintenance services to identify door issues, repair worn or damaged components, and keep your elevator operating safely and reliably. Contact Chicago Elevator to schedule your service.

iStock 1386885905

Lake Effect Weather & Your Elevator: Hidden Risks for Chicagoland Properties

Chicago weather can be hard on buildings. Snow, ice, precipitation, temperature changes, and strong winds can create maintenance challenges that property owners and managers need to plan for.

For properties with elevators, lake effect weather can affect areas beyond the parts of the building people typically think about. Moisture, precipitation, salt, and temperature changes can affect elevator entrances and other parts of the system, creating conditions that can lead to operational problems.

Some of these weather-related issues are easy to overlook until they begin affecting elevator operation. Knowing what to watch for helps property managers spot potential problems and address them before they become more disruptive.

What Is Lake Effect Weather?

Lake effect weather occurs when cold air moves across a relatively warmer body of water, picking up heat and moisture before moving over land. In Chicago, Lake Michigan can contribute to localized weather changes, including periods of rain or snow, depending on the temperature and atmospheric conditions.

When this weather reaches a property, its effects can extend beyond what is visible outside the building. For an elevator system, changes in temperature, moisture, and building pressure can affect different components and how they operate.

5 Hidden Elevator Risks During Lake Effect Weather in Chicagoland

Lake effect weather can bring different combinations of snow, rain, moisture, strong winds, and temperature changes to the Chicagoland area. These conditions can affect different parts of an elevator system, from door equipment and mechanical components to electrical equipment and the hoistway. 

Here are five elevator risks that property owners and managers should watch for:

1. Ice & Snow Buildup Can Interfere With Elevator Door Operation

Snow, rain, and moisture can collect around elevator entrances and door sills. During freezing temperatures, that moisture can turn to ice around tracks and other areas involved in door movement.

Ice and snow buildup can restrict normal door movement or prevent doors from closing properly. Even when freezing is not an issue, moisture and debris around the entrance can interfere with operation.

Keeping elevator entrances and door areas clear of snow, ice, moisture, and debris can help reduce the risk of door problems. If doors begin sticking, moving differently, or failing to close properly, have the elevator system inspected by a qualified technician to identify the issue.

2. Cold Temperatures Can Affect Lubricant Performance

Cold temperatures can affect the way lubricants perform within mechanical elevator components. As temperatures drop, some lubricants can become more viscous, which may affect components that depend on proper lubrication.

The impact varies depending on the elevator system, the components involved, and the lubricant being used. Elevators exposed to significant temperature changes may require closer attention when temperatures drop sharply.

Regular maintenance can help confirm that the appropriate lubricants are used and that mechanical components operate as intended. Because traction and hydraulic systems use different components, the lubricants and cold-weather effects can vary between them.

3. Rain, Snow & Moisture Can Reach Electrical Components

Precipitation does not always stay outside the building. Rain, snow, and moisture can enter through building openings or be carried inside by people and equipment. Snow can also melt as temperatures rise, allowing water to collect around elevator equipment.

Moisture near electrical components can create maintenance and operational concerns. The level of risk depends on the elevator’s design, equipment location, and exposure to water. Older buildings can be especially vulnerable, since aging seals, entrances, and equipment give moisture more ways to reach sensitive components.

After heavy rain, snowfall, or snowmelt, check elevator areas for signs of water intrusion. A qualified elevator professional should evaluate moisture near electrical or mechanical components.

4. Strong Winds Can Affect Building Pressure Around the Hoistway

Lake effect weather can bring strong winds that interact with a building’s exterior and ventilation openings. In taller buildings, pressure changes can also interact with the vertical elevator hoistway.

These pressure differences can affect how hoistway doors operate in some buildings. Doors may become more difficult to open, close, or latch properly when building pressure changes significantly.

Because this issue is related to airflow and pressure rather than visible buildup, it can be easy to overlook when investigating elevator problems.

5. Freeze-Thaw Cycles Can Create Recurring Issues

Temperatures can move above and below freezing as weather changes, creating repeated cycles of melting and refreezing. Snow and ice can melt during warmer periods, while rain and other moisture can later freeze when temperatures drop again.

This repeated exposure can create new ice buildup around elevator entrances and other areas of the property. It can also allow moisture to reach areas that were dry when temperatures were higher.

Monitoring elevator areas through changing weather can help property teams identify recurring moisture, ice, and operational issues before they become larger problems.

10 Preventive Tips to Protect Your Elevator During Lake Effect Weather

Preventive measures should focus on the parts of the elevator system most likely to be affected by moisture, temperature changes, and changing conditions around the property. The following tips can help address these areas before they lead to elevator problems:

  1. Use Cold-Rated / Weather-Appropriate Lubricants. Have the elevator technician confirm that the lubricants used are appropriate for the temperatures the equipment may be exposed to.
  2. Schedule a Pre-Weather Maintenance Visit. Have the elevator professional check weather-sensitive components before periods of significant temperature changes or precipitation.
  3. Keep Door Sills and Thresholds Clear. Make sure elevator entrances are kept clear of snow, ice, salt, moisture, and debris that could interfere with door movement.
  4. Maintain Elevator Pit Drainage. Confirm that sump pumps and other water-management equipment serving the elevator pit are maintained and working properly.
  5. Address Water Intrusion. Have water intrusion around the elevator system addressed before it can reach electrical or mechanical equipment.
  6. Seal Areas Exposed to Outside Air. Ask the elevator professional to identify areas where unwanted outside air or moisture can enter the hoistway or machine room.
  7. Protect Electrical Equipment From Moisture. Have the elevator professional check whether electrical components are adequately protected from moisture and condensation.
  8. Review Weather-Related Service History. Review previous elevator service calls to identify recurring problems during periods of significant precipitation or temperature changes.
  9. Report Changes in Elevator Operation Early. Report recurring door problems, unusual sounds, leveling changes, or other operational changes before they become larger service issues.
  10. Keep Preventive Maintenance Current. Stay current with scheduled elevator maintenance so weather-related wear and equipment concerns can be identified before they lead to unexpected downtime. If you are reviewing your coverage, read our guide to what to look for in an elevator maintenance agreement

When Should You Call an Elevator Professional?

Some weather-related maintenance can be handled as part of routine property care, but elevator equipment problems require professional attention.

Contact an elevator professional if you notice:

  • Elevator doors sticking, failing to close, or operating differently
  • Changes in elevator movement or leveling
  • Unusual sounds during operation
  • Water or moisture around elevator equipment
  • Recurring problems during periods of changing weather
  • An elevator that stops operating

When these issues appear, an inspection can help identify the source before the problem becomes more disruptive. Elevator maintenance and repair require a qualified elevator professional and should not be handled by building staff alone. 

Get Expert Elevator Service From Chicago Elevator

Lake effect weather can create different challenges for elevators, depending on the building, equipment, and exposure to moisture, temperature changes, and precipitation. Our team understands these factors and can help identify what your elevator requires to stay reliable through changing weather.

If you want the experts on your side, our team is happy to help. Contact Chicago Elevator to discuss your elevator’s needs.

iStock 2246702036

How Long Do Elevator Permitting & Equipment Lead Times Take in Illinois?

We work with building owners on a wide range of elevator projects across Illinois, and one of the first questions we hear is how long the work will take. The answer depends on more than the installation itself. 

Permitting, equipment lead times, engineering, site preparation, approvals, and inspections can all affect the schedule.

In this guide, we break down how long elevator permitting, equipment lead times, installation, and final inspection typically take, what can affect those timelines, and why starting early can give you more flexibility when planning your project.

Understanding Permits, Equipment Lead Times & Installation

An elevator project has three major areas that need to be coordinated from the start:

  • Permitting: Determines what approvals are required before work can begin. The process depends on the building’s location, type of work, and the authority responsible for the project.
  • Equipment: Lead times include more than manufacturing and delivery. Equipment may need to be specified, engineered, approved, manufactured, and shipped before it reaches the job site.
  • Installation: Happens once the necessary approvals, equipment, and site preparation are in place. The schedule also needs to account for building operations and other trades working on the project.

These stages can overlap, but they are also connected. A delay in one stage can affect everything that follows, which is why it helps to consider the full project timeline from the start.

How Long Does an Elevator Permit Take in Illinois?

There is no single permit timeline for every elevator project in Illinois. The process can vary based on the building’s location, project scope, type of elevator work, completeness of the submission, and whether additional information or corrections are required.

Illinois requires a permit for an alteration or new installation of a conveyance or lift device. For municipalities that operate their own approved elevator programs, permits are handled locally. In other areas, the Illinois Office of the State Fire Marshal handles the permit.

The first step is to confirm which authority handles your project.

Elevator Permits in Chicago

Chicago has its own elevator permitting process through the Department of Buildings Elevator Bureau.

There is no published turnaround for an elevator permit. The timeline depends on the project and how complete the submission is, and corrections or requests for more documentation can extend the review. A complete, straightforward submission is often issued within a few weeks, but projects that also require a building permit for structural or major electrical work add a separate review on top of the elevator permit and can take considerably longer.

Start the permitting process early rather than waiting until the installation date approaches.

Elevator Permits Outside Chicago

Permit requirements and timelines vary by municipality.

Some Illinois municipalities run their own elevator safety programs and set their own review times, often a few weeks for a complete application. In other areas, the Office of the State Fire Marshal handles permitting directly. There is no single statewide processing time, so the same project can move at very different speeds depending on the address.

If you are working on multiple properties, do not assume the same process or timeline applies to every location. Confirm the requirements for each project before submitting plans.

Elevator Permits in Northwest Indiana

Northwest Indiana follows Indiana, not Illinois, requirements.

Indiana handles elevator permitting, licensing, and inspections through its own state system, and does not publish a standard processing time. The permitting steps and contractor licensing need to be checked separately, because a process that applies to an Illinois property may not apply across the state line.

What Can Delay an Elevator Permit?

Permit review can take longer when the submission requires corrections, clarification, or additional documentation.

Common causes include:

  • Incomplete project information
  • Missing or inconsistent drawings
  • Changes to the project scope
  • Equipment specifications that have not been finalized
  • Additional structural or architectural review
  • Code requirements identified during review
  • Documentation that does not match the proposed work

Illinois is also currently experiencing longer-than-normal processing times following the transition to a new elevator safety software system, according to the Office of the State Fire Marshal. The agency advises applicants to expect delays during the transition.

Potential delays are another reason to confirm current processing conditions rather than building a schedule around an old estimate.

How Long Does it take to get Elevator Equipment?

Equipment lead times can account for a significant portion of an elevator project’s schedule.

Elevator equipment is often manufactured or configured for a specific project. Controllers, door operators, hydraulic equipment, fixtures, traction equipment, and other components can have different production schedules.

The equipment, therefore, needs to be considered early, especially if a project has a fixed completion date.

When Does the Equipment Lead Time Start?

Equipment lead time does not necessarily begin when the contract is signed.

Before manufacturing can begin, the project may go through an engineering and submittal process. Submittals establish the technical details needed to manufacture and install the equipment, including layouts, power requirements, control specifications, fixture selections, cab signals, hoistway dimensions, and other project-specific requirements.

A simplified sequence looks like this: Project scope → Equipment selection → Engineering and submittals → Approval → Manufacturing → Delivery

If a decision is still open or a submittal needs to be revised, manufacturing may not be able to begin. That is why the time between signing a contract and receiving equipment can be considerably longer than the manufacturer’s stated production lead time.

Typical Elevator Equipment Lead Times

Actual equipment lead times vary by manufacturer, equipment type, specifications, availability, and current production schedules. Use the ranges below for planning, then confirm current figures before committing to a date.

ComponentTypical lead time
Controller8 to 16 weeks
Door operators6 to 12 weeks
Hydraulic power unit6 to 12 weeks
Hall and cab fixtures6 to 12 weeks
Custom cab interiors12 to 20+ weeks
Traction equipment12 to 20+ weeks

Custom or project-specific equipment can require additional time. If a component has a longer manufacturing schedule, identifying that early gives the project team more opportunity to adjust the plan.

Ordering components through separate channels can also add time. When the controller, fixtures, wiring, and hydraulic components come from unconnected sources, a project can stall on the one item nobody specified.

How Timelines Differ by Elevator Project

The factors above apply to elevator projects generally, but the timeline can look very different depending on what you are actually doing.

Elevator Modernization

Modernization involves upgrading or replacing components in an existing elevator system.

Depending on the scope, modernization upgrades may include the controller, door equipment, machine, hydraulic equipment, fixtures, wiring, or other major components. In our experience, a single modernization typically takes several weeks for installation, with the exact duration depending on scope.

The overall project can take considerably longer than the installation because planning, engineering, equipment procurement, permitting, approvals, and site preparation occur before the elevator is taken out of service.

Existing building conditions can also affect the schedule. The condition of the hoistway, pit, machine room, electrical systems, and other components may change the scope once the project is assessed.

Elevator Installation

An elevator installation has a different set of scheduling considerations.

In new construction, the elevator needs to be coordinated with the building’s design and construction. Hoistway dimensions, pit requirements, machine room or machine space requirements, electrical service, structural work, and other building systems must be incorporated early.

Equipment selection should therefore happen early enough for the architectural, structural, mechanical, and electrical teams to design around the elevator requirements.

New installations also involve both permit tracks, the elevator permit and the building permit, so the longer of the two review processes applies from the start.

The elevator can also be integrated into the broader construction schedule. A delay in equipment, site preparation, or installation can affect other trades and potentially the building’s planned completion.

Elevator Repair, Replacement, or Major Alteration

Repair, replacement, and alteration projects can vary significantly in scope and timeline. Elevator repair timelines can range from relatively short repairs to more involved work that requires replacement parts, permits, or changes to the existing system. 

A routine repair may take much less time than replacing a major component or completing a full modernization. The timeline depends on the issue, the equipment or parts required, permitting requirements, and how the work affects the existing elevator system.

For that reason, a project-specific assessment is more useful than applying a single timeline to every type of elevator work.

What Can Delay an Elevator Project?

Permitting and equipment are major parts of the schedule, but they are not the only sources of delay. Other common causes of delay include:

  • Scope changes made after engineering or equipment approvals
  • Site not ready when the installation crew is scheduled
  • Owner or board approvals taking longer than expected
  • Equipment arriving late, or the building not ready to receive it
  • Heavier permit volume during spring and summer filing season
  • Inspections and turnover left to the end of the schedule

Finalizing the scope early, confirming the site and approvals, and scheduling inspections up front are the simplest ways to keep these from compounding into months. If an elevator fails inspection, the required repairs and reinspection can add time before the elevator returns to service.

Why You Should Start Planning Early

Starting early does not mean every elevator project takes a year. It means giving the project enough time to account for the factors that can affect the schedule.

Delays also compound rather than sitting side by side. A two-week permit correction delays the submittal approval date, which delays the manufacturing slot, which delays installation into the next available crew window. A modest delay early in a project regularly becomes a month or more by the time it reaches the installation date.

Starting early gives building owners more time to:

  • Assess the existing elevator
  • Define the project scope
  • Determine permitting requirements
  • Compare equipment options
  • Complete engineering and submittals
  • Account for equipment manufacturing
  • Prepare the site
  • Coordinate with other contractors
  • Schedule inspections
  • Plan around building operations

It also gives the project more flexibility when something changes. If a permit requires corrections, there may still be room in the schedule. If equipment has a longer lead time, the project team has more time to evaluate options. If site preparation requires additional work, that work can be scheduled before the installation crew arrives.

Waiting until the desired installation date is closed removes much of that flexibility.

Working Backward From Your Target Date

One of the simplest ways to plan an elevator project is to start with the date you want the elevator operating and work backward.

For example, if a modernization needs to be completed by June, the planning process should begin months before the elevator is scheduled to go out of service.

A sample schedule could look like this:

  1. August or September: Complete the site assessment and define the scope.
  2. October: Review and approve the proposal.
  3. November and December: Complete engineering and equipment submittals.
  4. December through March: Manufacture equipment while permitting and site preparation move forward.
  5. March through May: Complete installation.
  6. May or June: Complete testing, inspection, and turnover.

This is an example, not a guaranteed timeline. The actual schedule depends on the project type, equipment, jurisdiction, approvals, and site conditions.

The point is to start far enough ahead that permitting, equipment, installation, and inspection do not become separate scheduling emergencies.

Plan Your Elevator Project Before You Need It

Permits, equipment lead times, and installation are all important parts of an elevator project’s schedule. Waiting until an elevator is out of service or a construction deadline is approaching can leave fewer options for addressing delays.

Starting early gives building owners more time to evaluate existing equipment, determine the right scope, navigate permitting, select equipment, and coordinate installation. Explore elevator services by industry to see how project needs can vary by building type.

We can help you understand the requirements and build a realistic project timeline. Contact us to discuss your project and determine when you should get started.

iStock 2228630183

Why Elevators Break Down Repeatedly in Older Buildings

Older buildings often have character, history, and craftsmanship that newer properties cannot match. However, one area where age can become a challenge is the elevator system. While many elevators are built to last for decades, years of daily use, aging equipment, and changing building demands can lead to more frequent breakdowns over time.

Understanding why elevators experience recurring problems can help building owners and property managers make informed decisions about maintenance, repairs, and modernization before small issues become major disruptions.

Why Older Elevators Experience More Frequent Breakdowns

Elevators are made up of hundreds of mechanical and electrical components that work together every day. Even with routine maintenance, these parts naturally wear down over time.

Older elevators may also rely on equipment that was designed decades ago. As technology advances, older systems can become less reliable, harder to repair, and more expensive to maintain. While age alone does not guarantee frequent breakdowns, it often increases the likelihood that components will need more attention.

Common Causes of Repeated Elevator Failures in Older Buildings

Over the years, we’ve worked on elevators in buildings of all ages and have identified several common reasons older elevator systems experience repeated breakdowns. Here are some of the most frequent causes:

Aging Mechanical Components

Like any mechanical system, elevator parts eventually wear out. Components such as door operators, cables, pulleys, rollers, bearings, and brakes experience constant movement throughout the day.

As these parts age, they may become less efficient or fail unexpectedly, leading to service interruptions. Regular preventative maintenance plans can help identify worn components before they fail, reducing unplanned downtime and extending the life of your elevator.

Outdated Control Systems

Some older elevators still operate with control systems that were installed decades ago. These systems may not respond as efficiently as modern controllers and can become increasingly difficult to troubleshoot.

Older electronic components may also be more susceptible to failures, especially if replacement parts are no longer readily available. Elevator modernization services can replace outdated technology with more reliable, efficient equipment.

Wear From Years of Heavy Use

Elevators in apartment buildings, office buildings, hotels, healthcare facilities, and commercial properties often complete thousands of trips every month.

Over many years, this constant use places stress on motors, doors, guide rails, and other critical components. Even well-maintained elevators eventually show signs of wear simply because of the number of operating cycles they complete.

Difficulty Finding Replacement Parts

One challenge with older elevator systems is that manufacturers may no longer produce certain replacement parts. When a replacement part has to be sourced from a specialty supplier or shipped from out of state, every elevator repair takes longer and costs more. This is also why non-proprietary elevators can be much quicker to fix.

Deferred Maintenance & Repairs

When maintenance visits are skipped or performed inconsistently, developing problems go undetected. Minor elevator issues rarely fix themselves. A small vibration, unusual noise, or slow door operation can gradually develop into a larger mechanical problem if left unaddressed.

Scheduling elevator maintenance services on a regular basis helps address minor concerns before they result in unexpected breakdowns or more costly repairs.

Changes in Building Usage

Many older buildings now serve different purposes than they did when they were originally constructed. A residential building may have become mixed-use, or an office building may now accommodate more tenants than it once did.

Increased traffic places additional strain on elevator equipment that may not have been designed for today’s level of demand.

Warning Signs That an Older Elevator Needs Attention

Repeated breakdowns rarely come without warning. The signals are usually there before a full failure occurs. Building owners and property managers should pay attention when an elevator starts showing any of the following:

  • Unusual sounds during operation. Grinding, squealing, or banging are signs that mechanical components are under stress.
  • Slow or inconsistent door operation. This points to worn door operators or misaligned tracks.
  • Erratic leveling at floors. This indicates issues with the drive system or control components.
  • Frequent nuisance trips or unexpected shutdowns. These suggest electrical or control system problems.
  • Increasing repair frequency. If the elevator is requiring service calls more often than it used to, the pattern is already established.

Each one is the system communicating that something needs attention. If these problems become more frequent, it may be time to contact a professional for an inspection to identify the underlying cause.

If your elevator just stopped working and you’re not sure what to do, follow our immediate steps.

How Preventive Maintenance Reduces Repeat Breakdowns

Regular maintenance inspections allow technicians to identify worn components before they fail and perform adjustments that keep the system operating smoothly.

A comprehensive maintenance program may include:

  • Inspecting mechanical and electrical components
  • Lubricating moving parts
  • Testing safety devices
  • Checking door operation
  • Monitoring control system performance
  • Replacing worn parts before they fail

Routine maintenance not only helps reduce unexpected breakdowns but can also extend the overall lifespan of the elevator system.

When Elevator Modernization Makes More Sense Than Continued Repairs

There comes a point in the life of an older elevator when continued repairs stop making financial sense. Each repair addresses one failure, but the underlying equipment keeps aging and the next failure is already developing somewhere else in the system.

Here’s what elevator modernization offers that repeated repairs don’t:

  • Lower long-term costs. The total cost of reactive repairs over two or three years often exceeds what a proper modernization would have cost.
  • Addresses root causes, not symptoms. Unlike individual repairs, elevator modernization replaces the aging components driving the breakdown cycle, not just the latest failure.
  • Current, reliable equipment. Modernization replaces aging control systems, drive components, door operators, and other high-wear parts with technology that’s actually serviceable today.
  • Code compliance. Modernization brings the elevator into compliance with current code requirements, reducing the risk of violations and failed inspections down the road.

For building owners dealing with a system that keeps breaking down, modernization is almost always the more practical long-term solution. 

Improve Your Building’s Reliability With Expert Elevator Services

Repeated elevator breakdowns are not something building owners have to accept. They’re a problem with a clear cause and a practical solution, and the solution almost always starts with honest diagnostics and a commitment to consistent maintenance.

Chicago Elevator works with building owners across Chicago and Northwest Indiana who are dealing with exactly this situation. We’ll tell you what’s actually driving the failures, what it will take to fix them, and whether repairs or modernization makes more sense for your building.

Contact us today to request a quote and we’ll lay out exactly what needs to happen next. 

iStock 1322198297

How to Get Your Elevator Certificate of Operation Reinstated

We’ve seen firsthand how overwhelming it can be to handle a suspended or canceled Elevator Certificate of Operation. The tenant pressure, the ADA obligations, and the deadlines are all landing at once. 

The biggest challenge is almost never the repair itself. It’s not knowing what the process requires, who oversees it, and finding the right expert to get it done correctly the first time.

Certificate reinstatement isn’t complicated, but it has to be done correctly, in the right order, through the right process for your specific building.

It can be a lot, and that’s why we put this guide together. We have compiled everything you need to act fast, follow the right process, and get your certificate reinstated with the right people on the job.

What Is an Elevator Certificate of Operation?

Every elevator in Illinois must have a valid Certificate of Operation to run legally. It’s the state’s confirmation that your elevator has been inspected, meets current safety standards, and is cleared to operate. It must be displayed inside the cab where occupants can see it.

When an elevator fails inspection, that certificate gets suspended or canceled. The elevator is out of service. And it stays out of service until the certificate is formally reinstated.

Two things worth knowing upfront:

  • Completed repairs alone aren’t enough to reinstate the certificate
  • Passing re-inspection alone isn’t enough either

The certificate has to be reinstated through the correct process before the elevator can legally run again.

Know Which Process Applies to Your Building Before You Start

Where your building is located determines who oversees the reinstatement process and how it is carried out. There are three different situations to understand, so confirming which one applies to your building before you start saves time and prevents unnecessary delays.

If Your Building Is in Chicago’s AIC District

For buildings in Chicago’s Central Business District, the process starts with you. Property managers or building owners are responsible for hiring a state-licensed third-party elevator inspection company to initiate the inspection and reinstatement process. Keep in mind that a percentage of AIC inspections are randomly selected for city audit, so keeping complete and accurate documentation throughout the process matters.

How to obtain your Certificate of Operation:

  1. Hire a licensed third-party inspection company
  2. Complete the annual inspection through an Authorized Technician
  3. Submit inspection results through the AIC Portal
  4. Pay applicable AIC fees
  5. Complete and obtain approval for any required repairs
  6. Download and display the Certificate of Operation through the AIC system

Once the certificate is downloaded and displayed in the cab, your elevator is legally cleared to return to service.

If Your Building Is in Chicago But Outside the AIC District

For buildings located outside of Chicago’s AIC district, the City of Chicago Department of Buildings (DOB) performs the annual inspection directly. There is no third-party AIC process or portal submission by the building owner.

How to obtain your Certificate of Operation:

  1. Coordinate the annual inspection with the City of Chicago Department of Buildings
  2. Successfully pass the annual inspection
  3. Complete and obtain approval for any required permit-related repairs
  4. The City issues the Certificate of Operation directly

Once all required repairs are approved, the city issues your Certificate of Operation directly and your elevator is legally cleared to return to service.

If Your Building Is in the Suburbs

Suburban buildings often follow an entirely different process. Unlike Chicago, there is no single standard that applies across all municipalities. Certificate of Operation requirements are governed by the Illinois Office of the State Fire Marshal (OSFM) or the local Authority Having Jurisdiction (AHJ), and requirements can vary significantly from one municipality to another. Building owners are responsible for ensuring annual inspections and required testing are completed before their Certificate of Operation expires.

How to obtain your Certificate of Operation:

  1. Schedule the required annual inspection and Category testing with your elevator contractor and licensed third-party inspector
  2. Ensure all required testing is witnessed in accordance with your jurisdiction’s requirements
  3. Submit inspection reports, testing documentation, and applicable fees to the OSFM or local AHJ
  4. Complete any required repairs and reinspections if deficiencies are identified
  5. Once compliance is verified, the Certificate of Operation is issued or renewed through your applicable jurisdiction

Since some municipalities use the OSFM system while others maintain their own local portals, processes, and inspection agencies, confirm your specific jurisdiction’s process before proceeding.

The Bottom Line on Certificate of Operation Reinstatement

Regardless of where your building is located, the core sequence is the same every time:

  1. Every deficiency on the inspection report must be corrected exactly as cited by a licensed elevator mechanic
  2. A re-inspection must be passed
  3. The certificate must be formally reinstated through the applicable process for your jurisdiction

That order matters; the elevator can’t run until all three steps are complete. Returning the elevator to service before the certificate is formally reinstated creates legal liability and can make the situation significantly worse.

Before any work begins, go through the inspection report line by line with your contractor. Every deficiency needs to be corrected exactly as cited, not partially and not approximately. Misreading a citation is one of the main reasons elevators fail re-inspection. 

Learn more about our elevator repair services if you need a licensed contractor on site quickly

The 30-Day Clock Starts at Inspection

In Illinois, building owners are generally given 30 days from the date of the failed inspection to correct all cited deficiencies. Not from the date you read the report. Not from the date you called a contractor, from the date of the inspection itself.

Here’s what you need to know about the timeline:

  • A 60-day extension may be available but must be requested before the original window closes
  • The elevator typically stays out of service through the entire extension period
  • The certificate isn’t reinstated until the full process is complete

The correction window moves quickly when you account for contractor scheduling, parts lead times, inspector availability, and application processing. Acting immediately is the safest approach regardless of how much time you think you have.

Let’s Get Your Certificate Reinstated

A suspended certificate doesn’t have to mean a long shutdown. It means you need to act quickly and work with people who know the process.

Chicago Elevator has helped building owners navigate the reinstatement process across Chicago and the suburbs. We review the inspection report, complete the required corrections, coordinate re-inspection, and handle the process from start to finish. We know the requirements, we respond quickly, and we’ll keep you posted at every step.

Getting your certificate reinstated starts with one call. Contact us today and we’ll review your situation, scope the work, and give you a clear timeline. You can also request a quote and we’ll lay out exactly what needs to happen next.